Plumbing guide

No hot water: why your geyser is not working or heating

Last updated

If your geyser is not working, make four checks in this order: the breaker, the timer, recent power cuts and the water supply. You can do all four from the DB board, the controller and a tap. Anything beyond that, such as the element or thermostat, needs a professional.

This guide covers the usual causes of no hot water, which of them are electrical and which are plumbing, and what is safe to do yourself.

Geyser not working: what you can check yourself

The breaker at the DB board

Find the breaker labelled "geyser". If it has tripped, switch it fully off and then on once. If it trips again, stop and leave it off. A breaker that keeps tripping is reporting a fault, and resetting it repeatedly can make things worse.

The timer or controller

A timer with the wrong time is a common reason for a cold tank. After power cuts, mechanical timers run late by however long the power was off, so the geyser heats at the wrong hours. Check the clock against the real time.

If you have an electronic geyser controller, check the clock, the programmed heating times and the set temperature. If its display shows an error code, note the code for the plumber instead of resetting it over and over.

A recent power outage

The element cannot heat during an outage. A geyser that has only partly cooled recovers in under an hour, but a 150 litre tank heated from cold by a 3 kW element takes about three hours. If the water is still cold well after that, move on.

Is it the geyser, or the water?

No water at all from the hot tap is a supply problem, not a heating one. Hot water with weak flow, while the cold taps run normally, points to a blocked pressure control valve strainer or a valve that is partly closed. See low water pressure and our pressure valve guide.

Element, thermostat and tripping

If the checks above are fine, the usual causes are inside the geyser:

  • Thermostat. It switches the element on and off to hold the set temperature, and it has a safety cut-out that trips if the water overheats. A cut-out that has tripped can be reset by a professional, but one that trips again means the thermostat needs replacing.
  • Element. The heating element burns out with age, and scale from hard water shortens its life. If the breaker holds and there is still no heat, the element is the likely cause. It is tested with a meter.
  • Earth leakage tripping. A failing element, or water seeping past the element gasket onto the terminals, trips the earth leakage and may take other circuits down with it.

Do not open the cover plate yourself. The terminals behind it are live unless the circuit is isolated, and the element is bolted into a tank of pressurised water. Switch off at the DB board and leave it to a plumber or electrician.

Typical costs

Published South African cost guides put a fitted thermostat at about R700 to R1,500 and a fitted element at about R900 to R2,000. A replacement mechanical timer is put at R300 to R600. These are market estimates, not CopperTap prices. Our geyser element replacement cost guide explains what moves the price. CopperTap's labour is R550 per hour in standard hours with a R450 call-out, materials extra, as shown on the prices page.

Electrician or plumber?

It depends on where the fault is.

Symptom Who to call
Sparks, burning smell or scorch marks at the DB board Electrician. Switch off the main switch if it is safe to reach
Faulty timer, isolator or wiring to the geyser Electrician
Breaker or earth leakage trips whenever the geyser is on Plumber or electrician. Usually the element
Water leaking, valve dripping or overflow running Plumber
Tank leaking or burst Plumber
Element or thermostat failure Either. Ask first

Elements and thermostats sit on the border between the trades. The part is fitted to the geyser, which plumbers work on daily, but it is connected to the electrical circuit, and electrical installation work falls under the electrical regulations. Many geyser plumbers replace both parts as routine. Ask whoever you book whether they do the job and what paperwork you will receive.

When no hot water means something worse

Some combinations point to a bigger problem:

  • No hot water and the overflow pipe running hot. The thermostat may have stuck on and the safety cut-out has tripped. Leave the geyser off. See geyser overflow pipe dripping.
  • Lukewarm water that runs out quickly. This can mean a failing element, a thermostat set too low or heavy sediment in the tank.
  • Brown water, rumbling or a damp ceiling. The tank may be near the end of its life. See geyser leaking.

If the tank is old, replacement may be better value than repair. See geyser replacement cost.

Thermostat setting, scale and age

A thermostat set too low gives lukewarm water that looks like a fault. Kwikot advises a setting of at least 60 degrees Celsius throughout the year. On most geysers the dial is behind the cover plate, so have it checked during a service instead of opening the cover yourself.

Scale and sediment reduce hot water gradually. Sediment at the bottom of the tank takes up space and insulates the water from the element, so the geyser runs longer for less. Kwikot advises a service every two years in hard or poor water, and every three to four years otherwise. If your geyser is past about 10 years and heats poorly, ask the plumber whether the tank is worth repairing.

What to tell the plumber

The diagnosis is faster and cheaper if you can say:

  • when the hot water stopped, and whether there was a power outage that day,
  • whether the breaker has tripped, and how many times,
  • whether a timer or controller is fitted, and what it shows,
  • whether water is dripping from the overflow pipes or the ceiling,
  • how old the geyser is and when it was last serviced.

For help, see geyser repairs, the emergency plumber page, or book a plumber.

Sources

  • Kwikot, geyser maintenance guidance (thermostat setting and service intervals)
  • South African booking-platform cost guides and a geyser comparison site (market price ranges)

Step by step

  1. Check the geyser breaker at the DB board Find the breaker marked geyser. If it has tripped, switch it fully off and then on once. If it trips again, leave it off and call a professional.
  2. Check the timer or controller If a timer or electronic geyser controller is fitted, check that the clock is right, the heating times suit your routine and the set temperature has not been changed.
  3. Allow for a recent power outage After load-shedding or an outage, a geyser needs time to reheat. Allow one to two hours for a tank that has gone cold before deciding there is a fault.
  4. Check whether it is the geyser or the water supply Open a hot tap. No water at all, or weak flow on hot only, is a supply or valve problem, not a heating problem.
  5. Book a plumber or electrician If the checks are fine and the water is still cold, the element or thermostat has probably failed. Leave the cover plate closed and book a professional to test it.

Frequently asked questions

Why is my geyser not heating?

The usual causes are a tripped breaker at the DB board, a timer or controller set so the geyser is not heating when you expect, a thermostat that has cut out or failed, or a burnt-out element. After a power cut, give the water time to reheat before assuming a fault.

How long does a geyser take to heat after a power cut?

A geyser that is only partly cooled recovers in under an hour. A 150 litre geyser with a 3 kW element takes about three hours to heat a full tank from cold. If there is still no hot water after that, check the breaker and timer, then call a plumber.

Do I need an electrician or a plumber for a geyser that is not heating?

Call an electrician for the DB board, the geyser circuit, the isolator or a timer. Call a plumber for leaks, valves and the tank. Elements and thermostats are replaced by both trades, so ask whoever you book whether they do the job and which certificate you will receive.

How much does it cost to replace a geyser element or thermostat?

Published cost guides put a fitted thermostat at about R700 to R1,500 and a fitted element at about R900 to R2,000. Those are typical South African market ranges, not CopperTap prices. Our element replacement cost guide breaks them down, and our own rates are on the prices page.

Why does my geyser breaker keep tripping?

A breaker or earth leakage that trips again straight after being reset points to a failed element, a faulty thermostat, damaged wiring or water reaching the electrical connections. Resetting it repeatedly is unsafe. Leave the geyser off at the DB board and book a plumber or electrician.

Need a plumber in Pretoria East?

Tell us your suburb and what is wrong. Our emergency service runs 24 hours a day, 7 days a week.

Call 086 999 0999