Plumbing guide
Pressure valve on a geyser: what it does and which rating you need
Last updated
The pressure valve on a geyser is the pressure control valve, often shortened to PCV. It sits on the cold water supply and reduces municipal pressure to what the geyser tank is rated to hold. Every mains-pressure geyser should have one.
The names cause confusion. Plumbers also call it a pressure reducing valve. People search for it as a "pressure release valve" or "pressure relief valve", but those names fit the safety valve on the tank better. This page covers the valve on the cold supply. If your geyser is dripping and you are not sure which valve is responsible, the comparison table below will help.
What does the pressure valve on a geyser do?
It does two jobs.
It reduces pressure. Municipal pressure varies through the day and can be well above what a geyser is built for. The valve holds the pressure entering the geyser at a fixed level, normally 400 kPa or 600 kPa.
It relieves expansion. Water expands as it heats, and a full, sealed tank has no room for the extra volume. Most pressure control valves have an expansion relief outlet that releases a small amount of water during heating, through a pipe that ends outside. That is why a slow drip from that pipe while the geyser heats is normal. Our overflow pipe guide explains how to tell a normal drip from a fault.
The valve also has a strainer that catches grit. After municipal pipe repairs or a burst main, the strainer can clog and the flow at your hot taps drops. A plumber can often clean it without replacing the valve.
Many homes are plumbed so that the same valve feeds the cold side of the mixers as well. That gives balanced hot and cold pressure, which showers and mixer taps need to hold a steady temperature.
Where is the pressure valve on a geyser?
It is on the cold water pipe that feeds the geyser, before the geyser's inlet. In many houses it is in the roof space close to the geyser. In others it is on an outside wall where the supply pipe rises to the roof. Look for a brass or polymer valve body with an arrow showing the direction of flow, usually with a small pipe leading away from its relief outlet.
The safety valve is the one screwed into the geyser itself. If you cannot tell which is which, ask a plumber to point them out during a visit. Do not unscrew or adjust anything on a connected geyser, and do not go into the roof space to inspect a live one.
What do 400 kPa and 600 kPa mean?
kPa stands for kilopascals. 400 kPa is about 4 bar and 600 kPa about 6 bar. These are the two ratings on most modern South African geysers. Older low-pressure geysers rated at 100 kPa or 200 kPa are still in service in some houses.
The rule is simple: the valve rating must match the geyser rating. The geyser's working pressure is on its data plate, along with the model and serial number. The safety valve must carry the same rating.
Fitting a 600 kPa valve to a 400 kPa geyser is the mistake to avoid, because the tank is then exposed to more pressure than it was built for. This happens when a valve is replaced with whatever the hardware shop had in stock. Read the data plate and have a qualified plumber confirm the match.
Pressure valve versus safety valve
Both are valves on a geyser system and both can drip, which is why people confuse them.
| Pressure control valve | Safety valve (TP valve) | |
|---|---|---|
| Job | Reduces mains pressure every day | Relieves dangerous temperature or pressure |
| Position | On the cold supply, before the geyser | Screwed into the geyser tank |
| Releases water when | Water expands during heating (expansion relief outlet) | Pressure or temperature passes a safe limit |
| Normal behaviour | Slow drip while heating | Stays shut |
| Fault sign | Steady drip when the geyser is not heating | Constant or heavy discharge, hot water or steam |
SANS 10254, the installation standard for fixed electric storage water heaters, calls for both, together with a drip tray and vacuum breakers. Our safety valve guide covers the second valve in full.
Geyser pressure valve leaking: signs of failure
A leaking pressure valve is the usual reason people look this up. Check where the water comes from and when.
- Steady dripping from the relief outlet when the geyser is not heating. The relief seat is dirty or worn, or the reducing part of the valve has failed and is letting full mains pressure through.
- Dripping that is worst late at night. Municipal pressure tends to rise when demand is low, which shows up a valve that is no longer reducing properly.
- Weak flow at the hot taps while the cold taps are fine. The strainer or cartridge may be blocked.
- Water or staining on the valve body or its joints. The valve or its connections are leaking and need attention.
If the discharge is heavy, switch the geyser off at the DB board and close the geyser's isolation valve if you can reach it safely. Then book a plumber.
A geyser comparison site's repair guide puts a replacement pressure control valve, fitted, at roughly R1,200 to R2,500. That is a typical South African market range, not a CopperTap price. Our rates are R450 call-out and R550 per hour in standard hours, with materials extra, as shown on the prices page.
How long does a pressure valve last?
There is no fixed service life. Water quality matters more than age: grit and scale wear the seat and block the strainer. Kwikot recommends a geyser service every three to four years where water quality is good and every two years where it is poor or hard. Have the valve checked and its strainer cleaned at each service.
When to call a plumber
Call one if the valve drips constantly, if your hot taps run weak, if you have had a new geyser fitted and are unsure the valve was changed to match, or if you cannot tell which valve is dripping. A geyser held at the wrong pressure wears out faster and can fail.
For related problems, see geyser repairs, low water pressure and geyser leaking, or book a plumber.
Sources
- Kwikot, geyser compliance (SANS 10254) and geyser maintenance guidance
- A South African geyser comparison site's troubleshooting guide (market price range)
Frequently asked questions
What is the pressure valve on a geyser?
It is the pressure control valve, also called a pressure reducing valve, fitted on the cold water supply to the geyser. It reduces municipal pressure to the level the geyser is built for. Most have a built-in expansion relief outlet that lets out a little water as the geyser heats.
Why is my geyser pressure valve leaking?
A slow drip from the relief outlet while the geyser heats is normal expansion. A steady drip when the geyser is not heating usually means the relief seat is dirty or worn, or the valve is no longer controlling pressure. Water from the valve body or its joints means it needs replacing.
What does 400 kPa or 600 kPa on a geyser valve mean?
kPa is kilopascals, a unit of pressure. A 400 kPa valve or geyser works at about 4 bar and a 600 kPa one at about 6 bar. The valve rating must match the working pressure on the geyser's data plate, so check the plate before buying or fitting anything.
How do I know if my geyser pressure valve is faulty?
Common signs are steady dripping from the relief outlet when the geyser is not heating, weak flow at the hot taps because the valve's strainer is blocked, or water on the valve body. Each can have other causes, so have a plumber confirm before anything is replaced.
Is the pressure valve the same as the safety valve on a geyser?
No. The pressure control valve sits on the cold supply and manages pressure every day. The safety valve, also called the temperature and pressure relief valve, is fitted to the tank and opens only when temperature or pressure becomes unsafe. A geyser needs both, and neither can do the other's job.
Can I replace a geyser pressure valve myself?
We would not. The valve sits on the pressurised supply to a geyser, its rating must match the geyser, and the work should be tested and certified. Switch the geyser off at the DB board and book a plumber. With the right part it is a short job.