Safety valve on a geyser: what it does and what dripping means
Last updated
The safety valve on a geyser is a temperature and pressure relief valve, usually called a TP valve. It is the last line of defence. If the thermostat fails and the water overheats, or pressure climbs past the tank's rating, the valve opens and lets water out so the tank does not rupture.
It sits in the roof with the geyser and discharges through a pipe to the outside, so most people only notice it when that pipe starts running. This guide covers what the valve does, what a drip means, how it is tested and when to replace it.
What does the safety valve on a geyser do?
It opens only when it has to. The valve has a spring set to the geyser's rated pressure and a temperature probe that reaches into the hot water at the top of the tank. Too much pressure or too much heat opens it. SANS 10254 requires the valve, and requires its discharge to be piped to the outside of the building.
The valve's pressure rating, usually 400 kPa or 600 kPa, must match the rating on the geyser's data plate.
How is it different from the pressure valve?
The safety valve protects against a failure. The pressure control valve on the cold supply works every day, reducing mains pressure and releasing expansion water as the geyser heats. Our pressure valve guide has a side-by-side table of the two.
Why is my geyser safety valve leaking or dripping?
A leaking geyser safety valve is the usual reason people look this up, whether they call it the safety valve, the relief valve or just "the geyser valve". Work out when it drips and how much.
| What you see | Likely meaning | What to do |
|---|---|---|
| Slow drip only while the geyser heats | Expansion water. Normal if it comes from the pressure control valve's relief outlet. If it comes from the safety valve, the expansion relief is missing or not working | Have it checked at the next visit |
| Drip that carries on when the geyser is not heating | Worn or dirty valve seat, or too much supply pressure | Book a plumber this week |
| Strong or continuous flow | Thermostat failure or overpressure | Switch off at the DB board. Book a plumber the same day |
| Steam or very hot water | Overheating. The valve is doing its job | Switch off at the DB board, keep clear, call a plumber now |
From outside you often cannot tell which valve a pipe belongs to. The safety valve discharge, the expansion relief pipe and the drip tray drain can end side by side on the same wall. A plumber traces the pipe back to its valve before replacing anything, because changing the wrong valve leaves the fault in place. Our overflow pipe guide shows how to observe the pipes safely and what each pattern means.
Never block the discharge pipe
If the drip annoys you, do not cap, plug, kink or tie off the pipe. A safety valve that cannot discharge leaves an overheating geyser with no way to release pressure, and the tank can rupture. Fix the cause, not the symptom.
How is a geyser safety valve tested?
The valve has a test lever. Lifting it briefly should release a burst of hot water down the discharge pipe, and the flow should stop cleanly when the lever is released. A valve that will not lift, or keeps running afterwards, has failed.
We would not do this yourself. The water is very hot, the valve is usually in the roof space on a live geyser, and a valve that sticks open will empty hot water until the supply is shut. Ask a plumber to test it during a service. Kwikot advises a service every three to four years where water quality is good, and every two years where it is poor or hard.
When does a safety valve need replacing?
Replace it if it:
- drips constantly, even when the geyser is cold,
- will not close fully after a test,
- will not lift at all,
- is corroded, scaled up or leaking at its body or thread.
There is no published service life that applies to every valve. Scale and corrosion decide it, so a valve in hard water ages faster. On an old geyser with its original valve, it is sensible to replace the valve at the next service.
A geyser comparison site's repair guide puts a relief valve replacement at roughly R500 to R900. That is a typical South African market range, not a CopperTap price. Our rates are R450 call-out and R550 per hour in standard hours, with materials extra, as listed on the prices page.
Who can replace a geyser safety valve?
A qualified plumber. The geyser has to be switched off at the DB board, isolated from the water supply and relieved of pressure before the valve comes out. The new valve must carry the right rating, and its discharge pipe must run to the outside without a tap, a cap or an upward loop that could trap water.
PIRB requires its licensed plumbers to certify work on hot water systems, so ask whoever does the job for a certificate. Our plumbing certificate of compliance guide explains what you should receive and how to verify it.
What happens if a geyser has no working safety valve?
The tank loses its protection against overheating. If the thermostat then sticks on, pressure and temperature keep rising until something gives. The usual result is a ruptured tank and a burst geyser flooding the ceiling. That is why the standard makes the valve compulsory and why insurers ask about compliance.
Why the discharge pipe has to end outside
The valve releases very hot water and sometimes steam. Discharge that ends in the roof space, or only into the drip tray, soaks insulation and ceiling boards and can go unnoticed for months. If you can see where the pipe ends, check that it is outdoors and pointing somewhere safe. If you cannot find it, tell the plumber.
If you suspect a fault, see geyser repairs or book a plumber. If water is already pouring out, follow our burst geyser steps.
Sources
- Kwikot, geyser compliance (SANS 10254) and geyser maintenance guidance
- A South African geyser comparison site's troubleshooting guide (market price range)
Frequently asked questions
What is the safety valve on a geyser?
It is a temperature and pressure relief valve, often called a TP valve. It is screwed into the geyser tank and opens to release water if temperature or pressure goes beyond safe limits. Its discharge must be piped to the outside of the building, not into the roof space.
Why is my geyser pressure relief valve leaking?
If the leak is from the valve on the tank, the seat may be worn or dirty, the pressure control valve may be letting in too much pressure, or the water is overheating. If the water is very hot or steaming, switch off at the DB board and call a plumber the same day.
Why is my geyser safety valve dripping?
On a correctly installed system the safety valve stays dry and expansion water leaves through the relief outlet on the pressure control valve. A dripping safety valve points to a worn seat, too much supply pressure or a missing expansion relief. A plumber should trace which valve the water is coming from.
How often should a geyser safety valve be replaced?
There is no fixed interval. Replace it when it drips constantly, will not close after being operated, will not lift when tested, or is corroded. Have it checked whenever the geyser is serviced, which Kwikot advises every three to four years, or every two years in poor or hard water.
Can I test my geyser safety valve myself?
We advise against it. The test means lifting a lever on a valve attached to a tank of very hot, pressurised water, usually in the roof space, and an old valve can stick open. Leave it to a plumber during a service, who can replace the valve immediately if it fails.
Is the safety valve compulsory on a geyser?
Yes. SANS 10254, the installation standard for fixed electric storage water heaters, requires a safety valve with its discharge piped to the outside of the building. Insurers can ask whether an installation met that standard when a geyser claim is assessed.