Plumbing guide
Geyser leaking: why it happens and what to do
Last updated
A geyser leaking water is a symptom, not a diagnosis. The water can come from five or six different places, and where it appears tells you what is wrong. That decides whether you need a small repair or a new geyser. If water is pouring through the ceiling, treat it as a burst geyser and follow those steps instead.
First, make it safe
- Switch the geyser off at the DB board.
- Close the isolation valve on the cold pipe to the geyser, or the main stopcock if you cannot reach it.
- Keep clear of hot water, and stay out of rooms where the ceiling sags or bulges.
- Do not touch wet wiring, light fittings or the DB board. If water has reached any of them, you need an electrician as well as a plumber.
Do not go into the roof space to inspect a geyser that is live or leaking.
Why is my geyser leaking? Diagnose by where the water is
Water from the overflow pipe
A slow drip while the geyser heats is expansion water and stops once the water is hot. A drip that carries on when the geyser is cold, a steady flow, or hot water and steam is a fault. Our overflow pipe guide explains which is which.
Water at valves and connections
A weeping joint, a corroded fitting or a dripping valve body shows as water at one point on the pipework. These are repairable. A geyser comparison site's repair guide puts a minor fitting or valve repair at roughly R600 to R1,200. That is a typical market range, not a CopperTap price. For the two valves most often involved, see the safety valve and pressure valve guides.
Water from the drip tray drain
A compliant geyser sits in a drip tray, and SANS 10254 requires the tray's outlet to drain to the outside of the building. If water runs from that pipe on an outside wall, the tray is catching something. A steady flow means the geyser or a joint above the tray is leaking.
That pipe is your early warning. Homeowners who never look at it usually discover the leak from a ceiling stain, long after the tray started draining.
Water from the tank body
Water on the outside of the tank casing, at a seam or dripping from underneath, away from any valve or joint, means the inner steel tank has corroded through. A sacrificial anode inside the tank slows corrosion, but once the anode is used up the tank itself is attacked. Brown or rusty hot water is a typical early sign.
This is a replacement, not a repair. See geyser replacement cost.
Stains on the ceiling below the geyser
Staining, damp, a mouldy smell or a sagging patch under the geyser could come from any of the above, or from a pipe in the roof. The geyser is the first thing to check. If the source cannot be found by looking, leak detection can locate it.
Geyser leaking from the element gasket
The element and thermostat sit behind a cover plate on the geyser. The element is bolted to the tank through a flange with a rubber gasket. When the gasket hardens with age and heat, water seeps out at the cover plate.
That water sits next to live terminals, which is why this leak often trips the earth leakage. Switch the geyser off at the DB board and leave the cover plate closed.
The repair means draining the tank, fitting a new gasket, usually with a new element, and testing for leaks before the power goes back on. A plumber should check the flange first. If the steel around it has corroded, a new gasket will not seal and the geyser needs replacing. Cost guides suggest element repairs are worth doing on geysers under about 10 years old, and less so on older tanks. Our element replacement cost guide has the price ranges.
Can a leaking geyser be repaired?
| Leak location | Repairable? |
|---|---|
| Overflow pipe, slow drip during heating | Nothing to repair |
| Safety valve or pressure control valve | Yes, by replacing the valve |
| Fittings and pipe connections | Yes |
| Element flange gasket | Usually, if the flange is sound |
| Tank body or seam | No. Replace the geyser |
The test is simple. If the water leaves through a part that can be unscrewed and swapped, the leak can be repaired. If it leaves through the steel of the tank, it cannot.
How old is your geyser?
Ask this before paying for any repair. Cost guides put typical geyser life at 8 to 12 years, and tank failures become common after about 10. Kwikot recommends a service every three to four years where water quality is good and every two years where it is poor or hard, including a check of the anode. An old geyser that has never been serviced and now leaks from the tank is not worth repairing.
What to do next
Leave the geyser off and the water closed, photograph any damage to ceilings or contents, and book a plumber. If you plan to claim, our guide on whether a burst geyser is covered by insurance explains what insurers look for. For repairs, see geyser repairs, or book a plumber.
What to tell the plumber
The diagnosis goes faster if you can say:
- where the water appears and when you first saw it,
- whether it gets worse while the geyser is heating,
- how old the geyser is and when it was last serviced,
- whether the overflow pipes or the drip tray drain outside are running.
A photo of the ceiling stain and of the pipes outside helps. If you have the certificate of compliance from the installation, keep it to hand.
Sources
- Kwikot, geyser compliance (SANS 10254) and geyser maintenance guidance
- South African booking-platform cost guides and a geyser comparison site (market price ranges and typical geyser life)
Step by step
- Switch the geyser off at the DB board Switch off the breaker marked geyser. This removes the shock risk from water near the element and wiring, and stops the element heating a tank that may be losing water.
- Close the water supply to the geyser Close the isolation valve on the cold pipe feeding the geyser if you can reach it without going near the leak. If you cannot, close the main stopcock for the property.
- Keep clear of hot water and sagging ceilings Leaking water can be hot enough to scald. Stay out of any room where the ceiling is stained, sagging or bulging, and do not touch wet wiring, light fittings or the DB board.
- Note where the water is coming from From a safe position, note whether the water is at the overflow pipes outside, at a valve or pipe joint, at the drip tray drain, or coming through the ceiling. Take photographs for the plumber and your insurer.
- Book a plumber Tell the plumber where the water appears, how old the geyser is and whether the leak gets worse during heating. Leave the geyser off until it has been checked.
Frequently asked questions
Why is my geyser leaking?
The common causes are expansion water from the overflow pipe, a worn valve, a loose or corroded fitting, a perished element gasket, or a corroded tank. Where the water appears points to the cause. Valves, fittings and gaskets can be repaired. A leak through the tank itself means the geyser must be replaced.
Can a leaking geyser be repaired?
It depends where it leaks. Valves, pipe fittings and the element gasket can be repaired or replaced. A leak through the tank body is corrosion, and there is no lasting repair for it. Patching or welding a corroded tank does not make it safe, so the geyser is replaced.
Why is my geyser leaking from the element gasket?
The element is sealed to the tank by a rubber gasket on its flange. Over time the gasket hardens and water seeps out behind the cover plate, sometimes tripping the earth leakage. Switch off at the DB board, leave the cover closed, and have a plumber drain the tank and fit a new gasket.
Is a leaking geyser dangerous?
It can be. Water near the element, wiring or DB board is a shock risk, the water may be scalding, and a leaking tank may be close to failing. Switch the geyser off at the DB board, close the water supply to it, keep clear, and call a plumber.
How do I know if my geyser is leaking in the ceiling?
Look for damp patches, brown staining or a bulge in the ceiling below the geyser, the sound of dripping, or water running from the drip tray's drain pipe outside. The tray catches leaks and drains them outdoors, so water at that pipe means something above it is leaking.
How long can a geyser leak before it bursts?
Nobody can give a reliable time. A weeping fitting can carry on for months. A leak from the tank body means the steel has corroded through, and it can fail without further warning. Treat any tank leak as urgent, switch off at the DB board and book a plumber.